RNC Data Sheet Documentation Back

Ex conduit glands

RNC_picRNC_ON

Features

  • Manufactured from plain brass, nickel plated brass or stainless steel
  • Two seal options to provide -40ºC to +100ºC (EPDM seal) or -65ºC to +220ºC with silicon seal.
  • ATEX certified: Ex II 2 GD / Ex d IIC Gb / Ex e IIC Gb / Ex tb IIIC Db / Ex I M2 / Ex I Mb / Ex e 1 Mb
  • Ingress Protection to IP66 (dustproof and water tight) or IP68 (underwater tested)
  • Male:Female dimensions: M16 x 1.5 to M90 x 2.0

Certification

INERIS 06 ATEX 0014X

Ex protection type (EN 50018/IEC 60079-1 and EN 50019/IEC 60079-7)

Ex II 2 GD

Ex d IIC Gb

Ex e IIC Gb

Ex tb IIIC Db

Ex I M2

Ex I Mb

Ex e 1 Mb

Ingress protection levels

IP66 and 68 (EN 60529/IEC 60529)

Ambient temperature

-40ºC to +100ºC (EPDM seal) or -65ºC to +220ºC with silicon seal

Description

RNC conduit cable glands are specially designed to accept ISO and NPT conduits installed in hazardous areas. RNC conduit glands are manufactured from plain brass, nickel plated brass or stainless steel, with two sealing options to provide -40ºC to +100ºC (EPDM seal) or -65ºC to +220ºC with silicon seal. ATEX certified: Ex II 2 GD / Ex d IIC Gb / Ex e IIC Gb / Ex tb IIIC Db / Ex I M2 / Ex I Mb / Ex e 1 Mb. Ingress Protection to IP66 (dustproof and water tight) or IP68 (underwater tested).  Dimensions range from: M16 x 1.5 to M90 x 2.0 and NPT 3/8″ to NPT 3″.

Product Code Size Clamping Range Hexagon nut size Thread length
Male Female
RNC16KNP1616 M16 x 1.5 M16 x 1.5 4.0 10.0 24/24 15
RNC20KNP2020 M20 x 1.5 M20 x 1.5 5.5 13.0 30/32 18
RNC25KNP2525 M25 x 1.5 M25 x 1.5 8.0 18.0 35/36 18
RNC32KNP3232 M32 x 1.5 M32 x 1.5 13.0 24.0 42/45 22
RNC40KNP4040 M40 x 1.5 M40 x 1.5 21.0 30.0 48/50 22
RNC50KNP5050 M50 x 1.5 M50 x 1.5 24.0 36.0 55/57 24
RNC63KNP6363 M63 x 1.5 M63 x 1.5 36.0 45.0 68/67 24
RNC75KNP7575 M75 x 1.5 M75 x 1.5 45.0 54.0 80/80 28
RNC90AKNP9090 M90 x 2.0 M90 x 2.0 54.0 62.0 100/100 28
RNC90BKNP9090 M90 x 2.0 M90 x 2.0 60.0 68.0 100/100 28
RNC160375KNP NPT 3/8” NPT 3/8” 4.0 10.0 24/24 15
RNC20050KNP NPT ½” NPT ½” 5.5 13.0 30/32 18
RNC25075KNP NPT ¾” NPT ¾” 8.0 18.0 35/36 18
RNC32100KNP NPT 1” NPT 1” 13.0 24.0 42/45 22
RNC40125KNP NPT 1 ¼” NPT 1 ¼” 21.0 30.0 48/50 22
RNC50150KNP NPT 1 ½” NPT 1 ½” 24.0 36.0 55/57 24
RNC63200KNP NPT 2” NPT 2” 36.0 45.0 68/67 24
RNC75250KNP NPT 2 ½” NPT 2  ½” 45.0 54.0 80/80 28
RNC90A300KNP NPT 3” NPT 3” 54.0 62.0 100/100 28
RNC90B300KNP NPT 3” NPT 3” 60.0 68.0 100/100 28

 

Technical data (Extract) (For detailed information please click here)

Protection class

IP 66 and 68 (EN 60529/IEC 60529)

Dimensions

see data sheet

Material

Plain brass, nickel plated brass or stainless steel

Weight

see data sheet

Resistance

Impact resistance – see data sheet

Documentation

RNC Ex Conduit Glands Data Sheet

Declaration of Conformity

Customer requirements

Operating Instructions